Abstract
After evaluating the understanding of 36 nurses on how to manage cuff pressure in endotracheal tube and checking the cuff pressure on 30 on respiratory patients in ICU and Surgical ICU, Da Nang Hospital.
Results: 47.2% nurses hadn't known the range of safety cuff pressures and 36.1% didn't understand the indications of take the pressure out. More than 50% cuff pressures were measured out of the safety range, especially 18,3% were exceeded 45 cm H2O related tracheal injury after 15 minute. Only 46.7% of pressures were in the range of 20 cm H2O -> 30 cm H2O.
Recommendation: Nurses need to be trained and updated the knowledge on controlling the cuff pressure. Endotracheal tube cuff pressure should be set and monitored with a manometer.
References
Nguyễn Đạt Anh (2008), Những vấn đề cơ bản trong thông khí nhân tạo, Nhà xuất bản Y học, tr.346-347.
Huỳnh Anh (2006), Biến chứng mở khai khi quản tại bệnh viện Tai mũi họng trung ương, Luận văn tốt nghiệp chuyên khoa cấp II, Hà Nội. 3. Bộ Y tế (2002), “Chăm sóc người bệnh đặt ống nội khí quản”, Quy trình chăm sóc người bệnh tập 1, Nhà xuất bản Hà Nội, tr.23–25.
Bộ Y tế (2002), “Chăm sóc người bệnh thở máy”, Quy trình chăm sóc người bệnh tập 1, Nhà Xuất bản Hà Nội, tr.27-29.
Vũ Văn Đính (1989), “Đặt nội khí quản”, Kỹ thuật hồi sức cấp cứu, Nhà xuất bản Y Hà Nội,
tr.14-22.
Conti M, Pougeoise M, Wurtz A et al (2006), Management of postintubation tracheobronchial ruptures, Chest, 130, pp.412-418.
Diaz E, Rodriguez AH, Rello J (2005), Ventila- tor-associated pneumonia: issues related to the artificial airway, Respir Care, 50, pp.900-906. 11. Sengupta et al (2004), Endotracheal tube cuff pressure in three hospitals, and the volume re- quired to produce an appropriate cuff pressure. BioMed Central Ltd.
Seegobin RD, van Hasselt GL (1984), Endo- tracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs, Br Med J, 288, pp.965-968.
Nguyễn Thị Mỹ Thắm (2010), “Khảo sát đặc 13. Vyas D, Inweregbu K, Pittard A (2002), Mea- điểm tổn thương hẹp thanh khí quản sau đặt nội khí quản lâu ngày”, Y học TP. Hồ Chí Minh, 1,
tr.277-283.
Alexandre Duguet, Saad Nseir, Continuous con- trol of endotracheal cuff pressure and tracheal wall damage, http://ccforum.com/content/11/5/ R109.
Alrich-Pur H, Hrska F, Krafft P et al (2006), Comparison of mucosal pressures induced by cuffs of different airway devices, Anesthesiol- ogy, 104, pp.933-938.
surement of tracheal tube cuff pressure in criti- cal care, Anaesthesia, 57, pp.275-277.
Duguet A, D'Amico L, Biondi & et al (2007), Control of tracheal cuff pressure: a pilot study using a pneumatic device. Intensive Care Med, 33, pp.128-132.
Valencia M, Ferrer M, Farre R et al (2007), Automatic control of tracheal tube cuff pres- sure in ventilated patients in semirecumbent position: a randomized trial, Crit Care Med, 35, pp.1543-1549.
| Published | 13-07-2012 | |
| Fulltext |
|
|
| Language |
|
|
| Issue | No. 11 (2012) | |
| Section | Original article | |
| DOI | ||
| Keywords |

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Copyright (c) 2012 Journal of Clinical Medicine Hue Central Hospital